Sterilization Equipment
Horizontal Autoclave (Double Door)
Model: LHA-DD Series
Double-door horizontal autoclave enabling clean/sterile barrier workflow for pharma and hospital CSSDs.
- Custom-built to your specifications
- Pre-dispatch quality testing
- Installation & training support
- Comprehensive manufacturer warranty
Product Overview
Our horizontal Steam Sterilizer are widely used in various bulk laboratories/Hospital for their day to day studies on scale sterilization procedures where they give dryness of the sterilized medium a paramount importance and for that our sterilized media is prone to various micro-bacterial and viral infections. Having a specialization in customers' requirements we have an expert team of making both standard and customized models Salient features Salient features
Cylindrical design triple walled horizontal autoclave mounted on a sturdy, heavy M.S. duly painted tubular stand
Inner chamber, door lid, jacket, boiler & outer jacket cover made of SS 304
Steam is generated in a separate boiler which is placed below the main body.
Lid is provided with Pressure locking system which prevents opening of the door while Steams inside the chamber.
Single hinged door and manual radial locking system made of mild steel nickel coated
Cylindrical design triple walled horizontal autoclave mounted on a sturdy, heavy M.S. duly painted tubular stand
Inner chamber, door lid, jacket, boiler & outer jacket cover made of SS 304
Steam is generated in a separate boiler which is placed below the main body.
Lid is provided with Pressure locking system which prevents opening of the door while Steams inside the chamber.
Single hinged door and manual radial locking system made of mild steel nickel coated
Technical Specifications
| Model | Inner dimension (inch) | Capacity (Ltrs.) | Heater Load | Sterilization Temp. & Pressure | Operating Pressure |
|---|---|---|---|---|---|
| LFAS – SSHC – 75 | 16”x 24” | 75 | 6 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 100 | 18” x 24” | 100 | 6 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 125 | 16” x 36” | 125 | 9 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 150 | 18” x 36” | 150 | 12 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 200 | 18” x 48” | 200 | 12 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 250 | 20” x 48” | 250 | 12 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |
| LFAS – SSHC – 350 | 24” x 48” | 350 | 18 kW | 1.2 Kg/cm2 (15- 18psi) at 121°C | From 10 psi to 20 psi |